Improving performance of the evaporative cooling system inside the greenhouses and its effect on tomato productivity (Record no. 60462)

MARC details
000 -LEADER
fixed length control field 03111cab a2200313Ia 45 0
001 - CONTROL NUMBER
control field u211460
003 - CONTROL NUMBER IDENTIFIER
control field SIRSI
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 160317s2015 ua ss b eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EAL
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title engbara
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) ART ASEJ V36 NO1 10
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Youssef, G. D. M
240 10 - UNIFORM TITLE
Uniform title Alexandria science exchange journal, 2015 v. 36 (1)
Medium [electronic resource]:
-- an international quarterly journal of science agricultural environments
245 10 - TITLE STATEMENT
Title Improving performance of the evaporative cooling system inside the greenhouses and its effect on tomato productivity
Medium [electronic resource].
246 15 - VARYING FORM OF TITLE
Title proper/short title تحسين أداء نظام التبريد التبخرى داخل البيوت المحمية وتأثيرها على إنتاجية الطماطم.
300 ## - PHYSICAL DESCRIPTION
Extent p.80-94
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes references.
520 ## - SUMMARY, ETC.
Summary, etc. An experimental study was conducted to determine the performance of two evaporative cooling systems, as well as the gradients of temperature and humidity along a greenhouse. The first system was the cooling unit, (CU) compared with the traditional fan-pad one, (F-P). The cooling unit was connected with two perforated ducts inside the greenhouse. The air temperatures and relative humidities on the longitudinal axis were measured outside and just after leaving the media and at each one meter from the pad media. They were also, measured in the traverse axis parallel to the pad media at distances 0.5, 1.5, 2.5 and 3.5 m from the edge of the greenhouse. A steady state mathematical model was modified to predict the greenhouse air temperature according to the state of the air just leaving the cooling media. According to the experimental results, the non-uniform temperature changes were observed along the greenhouses for the two systems. The average temperatures of the CU greenhouse were 27.9, 30.4, 33.2, 29.1 and 27.9 °C for ou.tside ambient temperatures of 28.7, 32.4, 35.4, 32.1 and 29.4 °C, respectively. The ranges of temperature gradient inside the CU greenhouse were 2.1, 2.1, 2.2, 2.2, and 2.1 °C. While in the F-P greenhouse, they were 5.9, 7.4, 8.2, 5.9 and 6.1 °C for the same ambient temperatures. The average air temperature entering to greenhouse was approximately 6.82 and 7.09c lower than the outside air temperature for CU and F-P systems. The greenhouse of CU system was higher in the relative humidity than F-P one. The average relative humidities were 69.0 and 61.8% for the CU and Fp greenhouses, respectively, with increase percent 12.38%. The averages CU efficiencies were 77.55% and 74.79o/o in the first and second days, respectively, while they were 72.97% and 70.19% for the same days for F-P system.
546 ## - LANGUAGE NOTE
Language note Summary in Arabic.
596 ## -
-- 1
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tomatoes
General subdivision Yield
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tomatoes
General subdivision Cooling
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Tomatoes
General subdivision Effect of temperature on
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Greenhouses plants
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Yakout, T. R.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Mostafa, Doaa, M.
773 0# - HOST ITEM ENTRY
Title Alexandria Science Exchange Journal.
Related parts 2015.v.36(1)
International Standard Serial Number 1110-0176
Control subfield nnas
Record control number u193445
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="http://nile.enal.sci.eg/EALE/2015/ASEJ/3615/1/80.pdf">http://nile.enal.sci.eg/EALE/2015/ASEJ/3615/1/80.pdf</a>
Public note Full Text Article
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Articles
Source of classification or shelving scheme Library of Congress Classification

No items available.


Home | About ENAL | Collections | Services | Activities | Calendar | Contact us

7 Nadi El Sayed St., Giza, Egypt | Phone:02-33351121 +02-33351313 | 
| Email: enalegypt@gmail.com