Design, construction and performance evaluation of a solar drying unit of basil leaves / (Record no. 63159)

MARC details
000 -LEADER
fixed length control field cab a22 a 4500
001 - CONTROL NUMBER
control field u212596
003 - CONTROL NUMBER IDENTIFIER
control field ENAL
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 161019s2016 ua ss b eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EAL
Transcribing agency EAL
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract ara
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) ART MJAE V33 No1 6
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Imbabi, A. T.
9 (RLIN) 19422
240 10 - UNIFORM TITLE
Uniform title Misr journal of agricultural engineering, 2016 v.33 (1)
Medium [electronic resource].
245 10 - TITLE STATEMENT
Title Design, construction and performance evaluation of a solar drying unit of basil leaves /
Medium [electronic resource].
246 15 - VARYING FORM OF TITLE
Title proper/short title تصميم و تشييد و تقييم اداء وحدة تجفيف شمسى لأوراق الريحان
300 ## - PHYSICAL DESCRIPTION
Extent p.75-100
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes references.
520 ## - SUMMARY, ETC.
Summary, etc. Two similar solar drying units were designed, constnu.:ted and evaluated for drying basil leaves (Ocimum basi/icum 1.) as a medicinal and aromatic plant at initial moisture content of 590.73% (d.b) or 85.52%<br/>(w.b) under Fa;voum conditions by using heated air. Each d,)'ing unit consists ofa flat-plate solar collector. which oriented and tilted with an optimum tilt angle and. attached with drying chamber. The drying experiments were carried out to examine the effect of basil leaves thicknesses (2, 4 and 6 cm) and airflow rate (0.015 and 0.025 m3.sec·') on the basil leaves drying rate. The obtained results indicated that the daily average total solar radiation flux incident on the tilted solar collector surface (29.30 MJ m·'1.daf') was greater than that incident on the horizontal surface (24.30 MJm·'1.daJ'-') by 24. 58%. The output higher air temperatures were obtained at tlie lower airflow rate whereas; the energy gained to the air from the solar collector was relatively higher at the higher airflow rate as compared with the lower airflow rate. Consequently, the solarco/lector with the higher airflow rate increased the overall thermal efficiency by 5.46% as compared to the lower airflow rate. The moisture content ofdried basil leaves was strongly affected by the basil leaves thickness and the airflow rate. The final moisture content ofdried basil leaves rangedfrom (lJ.52% to 14.58% d.b) depending on the drying temperature cycle. Very small changes were observed in the colour and shape of heated-air dried basil leaves as compared to that dried at direct sun rays. The essential oil contents of dried basil leaves were slightly higher for the drying unit with the higher airflow rate as compared with the corresponding values obtained from the drying unit with the lower airflow at all basil leaves thicknesses.While on Contrast, total chlorophylls contents were slightly higherfor the<br/>drying unit with the lower airflow rate as compared with the<br/>corresponding values obtained from the drying unit with the higher<br/>aiifl9w at all basil leaves thicknesses. Effect of the individual variables<br/>(aiiflow rate, basil leaves thickness. moisture removed. and their<br/>interactions) on the drying rate was statistically analyzed Under the<br/>conditions of this study, the optimum depth to dry basil leaves by using<br/>heated air is 4 em.
546 ## - LANGUAGE NOTE
Language note Summary in Arabic.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Basil
General subdivision Drying.
9 (RLIN) 21398
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Drying apparatus
9 (RLIN) 21399
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Solar dryers.
9 (RLIN) 19425
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Abdel-Galil, H. S.
9 (RLIN) 19427
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Abdel-Kader, T. KH.
9 (RLIN) 19428
773 0# - HOST ITEM ENTRY
Related parts 2016.v.33(1)
Title Misr Journal of Agricultural Engineering.
Record control number u192786
Control subfield nnas
International Standard Serial Number 1687-384X
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://nile.enal.sci.eg/EALE/2016/MJAE/3316/1/75.pdf
Public note Full Text Article
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Articles AR
Source of classification or shelving scheme lcc
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total Checkouts Full call number Date last seen Price effective from Koha item type
    Library of Congress Classification     Main Main 07/11/2018   ART MJAE V33 No1 6 07/11/2018 07/11/2018 Articles

Home | About ENAL | Collections | Services | Activities | Calendar | Contact us

7 Nadi El Sayed St., Giza, Egypt | Phone:02-33351121 +02-33351313 | 
| Email: enalegypt@gmail.com