MARC details
000 -LEADER |
fixed length control field |
02654nab a2200289 a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
ENAL |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
211221s2021 ua mr ss ||| eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
EAL |
Transcribing agency |
EAL |
041 ## - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
Language code of summary or abstract |
ara |
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
ART MUJSSAE V12 No9 4 |
100 1# - MAIN ENTRY--PERSONAL NAME |
Personal name |
Abd Elamid, Soha G. |
9 (RLIN) |
33638 |
240 10 - UNIFORM TITLE |
Uniform title |
Mansoura university journal of soil sciences and agricultural engineering, 2021 v. 12 (9) |
Medium |
[electronic resources]. |
245 10 - TITLE STATEMENT |
Title |
Requirements Of balling chopped rice straw |
Medium |
[electronic resources] |
246 15 - VARYING FORM OF TITLE |
Title proper/short title |
متطلبات كبس قش الأرز المفروم |
300 ## - PHYSICAL DESCRIPTION |
Extent |
615 - 619 p. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Includes references. |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study aimed to identify the effect of the rice straw chopping process on the bales storage capacity. Chopping process of straw rice was carried out under three drum speeds, three feeding rates and three moisture contents of straw. Baling process was used to press chopped straw with three frequency speeds of plunger to press chopped straw, three feeding rates for chopped rice straw and different cutting lengths for chopped rice straw. The results were obtained the lowest average cutting length was7.88 mm with increasing speed of drum from 4.71 to 10.5m/s, and the minimum moisture content at 12%. The highest bale density was 144.6 kg / m³,under the frequency of press speed 0.45 m /s, for cutting length averages of less than 10 mm. The lowest storage capacity was 16.46 m³/fed, with a maximum compressing speed of 0.45 m /s and a feeding rate of 1.5Mg /h with the use of cutting averages less than 10mm. For the chopping process, the lowest energy requirement was8.9 kW.h/Mg at 4.71m/s and 12% moisture content with feed rate of 1.5Mg /h. Otherwise for the baling process, the lowest energy requirement was 5.67 kW.h /Mg at a compression speed of 0.24 m /s, feed rate of 3Mg/h and average cutting lengths greater than 20.5mm. The lowest production cost obtained when chopping straw was79.7LE /Mg with a speed of 4.71m/s, a moisture content of 12% and a feed rate of 1.5 Mg/h. The lowest production cost obtained when baling chopped straw was 98.5LE/ Mg with a speed of 0.24m /s and feeding rate of 3Mg /h.<br/>Keywords: rice straw - chopping - baling- storage. |
546 ## - LANGUAGE NOTE |
Language note |
Summary in Arabic. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Rice |
9 (RLIN) |
17812 |
General subdivision |
Residues |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Agricultural machinery |
9 (RLIN) |
17812 |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Rice |
General subdivision |
Machinery |
650 #3 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Rice straw |
650 #3 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Chopping |
9 (RLIN) |
26015 |
773 0# - HOST ITEM ENTRY |
Title |
Mansoura University Journal of Soil Sciences and Agirucultural Engineering. |
Related parts |
2021.v.12(9) |
International Standard Serial Number |
2090-3685 |
Control subfield |
nnas |
Record control number |
u183500 |
856 40 - ELECTRONIC LOCATION AND ACCESS |
Uniform Resource Identifier |
http://nile.enal.sci.eg/EALE/2021/MUJSSAE/1221/9/615.pdf |
Public note |
Full Text Article. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Articles |
AR |
Source of classification or shelving scheme |
alc |