Construction and evaluation of refrigerator for green bean using peltier effect | [electronic resource]. (Record no. 68251)

MARC details
000 -LEADER
fixed length control field 02346nab a2200277 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field ENAL
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220912s2022 ua ss b eng d
040 ## - CATALOGING SOURCE
Original cataloging agency EAL
Transcribing agency EAL
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
Language code of summary or abstract ara
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN)
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) ART MJAE V39 No3 4
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name El-Didamony, Mohamed I.
9 (RLIN) 32815
240 10 - UNIFORM TITLE
Uniform title Misr journal of agricultural engineering, 2022 v.39 (3)
Medium [electronic resource].
245 10 - TITLE STATEMENT
Title Construction and evaluation of refrigerator for green bean using peltier effect
Medium [electronic resource].
246 15 - VARYING FORM OF TITLE
Title proper/short title إنشاء وتقييم مبرد الفاصوليا الخضراء باستخدام تأثير بلتيير
300 ## - PHYSICAL DESCRIPTION
Extent p.409 – 424.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographic reference.
520 ## - SUMMARY, ETC.
Summary, etc. The creation of air conditioning and refrigeration was one of the biggest achievements. <br/>This study aimed to see how well the Peltier cooler system, to store vegetables and fruit, <br/>performed. To test performance, a thermoelectric module with (1, 2, 3, and 4) with and without fans, <br/>as well as two methods of attaching Peltiers, was employed (serial and parallel). The performance <br/>of the cooling system is determined by collected and analyzed data from the measuring system. <br/>The temperature distribution on each component of the cooling system is recorded using thermocouples <br/>connected to the data acquisition. Temperature for green bean cooling was 5 ?C, which provides perfect <br/>cooling for 14 days by 4 Peltiers, serial connection electric at average cooling load of 525.51 W in just <br/>5 min without freezing, with the use of a fan. The parallel connecting increases the consumed power from <br/>2.1 W to 16.8 W therefore the serial connection is reduced the power consumption to 0.26 W. The coefficient <br/>of performance (COP) values were reduced with the operating time to be 0.08 and 0.07 in parallel and serial <br/>connection respectively and one Peltier, but with the 4 Peltiers the COP values were 0.17 and 0.08 in parallel <br/>and serial connection<br/>
546 ## - LANGUAGE NOTE
Language note Summary in Arabic.
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Green bean
General subdivision Cooling
653 ## - NAL Term
Linkage hydroponic system
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name El-Sheikh, Faisal M.
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Amer, Mayie M.
773 0# - HOST ITEM ENTRY
Title Misr Journal of Agricultural Engineering.
Related parts 2022.v.39(3)
International Standard Serial Number 1687-384X
Control subfield nnas
Record control number u192786
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier http://nile.enal.sci.eg/EALE/2022/MJAE/3922/3/409.pdf
Public note Full Text Article
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Articles AR
Source of classification or shelving scheme alc
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Date acquired Total Checkouts Full call number Date last seen Price effective from Koha item type
    Alphabetical Classification     Main Main 09/13/2022   ART MJAE V39 No3 4 09/13/2022 09/13/2022 Articles

Home | About ENAL | Collections | Services | Activities | Calendar | Contact us

7 Nadi El Sayed St., Gizah, Egypt | Phone: +02-33351313 | Fax: 202 33351302 | Email: enalegypt@gmail.com