Investigate steady-state heat and mass balance for greenhouses pad-fan cooling system [electronic resource].

By: Contributor(s): Language: English Summary language: Arabic Description: p.1410-1437Other title:
  • تحقيق الإتزان الحراري والرطوبي لنظام التبريد التبخيري داخل الصوب .‪‪ [Added title page title]
Uniform titles:
  • Misr Journal of Agricultural Engineering, 2008 v.28 (4) [electronic resource].
Subject(s): Online resources: In: Misr Journal of Agricultural Engineering 2008.v.25(4)Summary: This research work aims to investigate the steady-state heat and mass balance for greenhouses that use pad-fan cooling system. It also studies the evaporative cooling system efficiency in fiberglass modified Quonset greenhouse. Dry-bulb and wet-bulb temperature were measured, relative humidity and cooling efficiency were calculated and predicted dry-bulb temperature and relative humidity inside the greenhouse throughout the proposed simple model was performed. Dry–bulb temperature and relative humidity were homogeneous altitude along the fiberglass greenhouse under investigation (16 m long, average of fan air velocity was 5.23 m/s and pad-face air velocity was 1.2 m/s). The obtained results showed that, the predicted data of dry-bulb temperature inside the greenhouse were validated well with that measured.
Star ratings
    Average rating: 0.0 (0 votes)
No physical items for this record

Includes references.

This research work aims to investigate the steady-state heat and mass balance for greenhouses that use pad-fan cooling system. It also studies the evaporative cooling system efficiency in fiberglass modified Quonset greenhouse. Dry-bulb and wet-bulb temperature were measured, relative humidity and cooling efficiency were calculated and predicted dry-bulb temperature and relative humidity inside the greenhouse throughout the proposed simple model was performed. Dry–bulb temperature and relative humidity were homogeneous altitude along the fiberglass greenhouse under investigation (16 m long, average of fan air velocity was 5.23 m/s and pad-face air velocity was 1.2 m/s). The obtained results showed that, the predicted data of dry-bulb temperature inside the greenhouse were validated well with that measured.

Summary in Arabic.