Investigate steady-state heat and mass balance for greenhouses pad-fan cooling system [electronic resource].
Language: English Summary language: Arabic Description: p.1410-1437Other title:- تحقيق الإتزان الحراري والرطوبي لنظام التبريد التبخيري داخل الصوب . [Added title page title]
- Misr Journal of Agricultural Engineering, 2008 v.28 (4) [electronic resource].
Includes references.
This research work aims to investigate the steady-state heat and mass balance for greenhouses that use pad-fan cooling system. It also studies the evaporative cooling system efficiency in fiberglass modified Quonset greenhouse. Dry-bulb and wet-bulb temperature were measured, relative humidity and cooling efficiency were calculated and predicted dry-bulb temperature and relative humidity inside the greenhouse throughout the proposed simple model was performed. Dry–bulb temperature and relative humidity were homogeneous altitude along the fiberglass greenhouse under investigation (16 m long, average of fan air velocity was 5.23 m/s and pad-face air velocity was 1.2 m/s). The obtained results showed that, the predicted data of dry-bulb temperature inside the greenhouse were validated well with that measured.
Summary in Arabic.