Desalination of brackish water utilizing air gap membrane distillation at two different cooling water levels [electronic resources].
Language: English Summary language: Arabic Description: 91-98 pOther title:- تحلية المياة المملحة بإستخدام وحدة تقطير غشائي ذو فجوة هوائية عند مستويين مختلفين لماء التبريد [Added title page title]
- Mansoura university journal of soil sciences and agricultural engineering, 2020 v. 11 (3) [electronic resources].
Item type | Current library | Call number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|
![]() |
Main | ART MUJSSAE V11 No3 4 (Browse shelf(Opens below)) | Available |
Browsing Main shelves Close shelf browser (Hides shelf browser)
Includes references.
In this work, the effect of two different cooling temperatures (Tc) on the permeate flux (Fp) and thermal efficiency (η) of air gap membrane distillation (AGMD) module was studied experimentally. All data were described statistically in terms of means, standard error for means (SE), standard deviation (SD) and coefficient of variation (C.V.). Data were subjected to the analyses of the variance (ANOVA) and multivariate analysis to test the significant effect of different feed and designs at p<0.05. Experiments were conducted using brackish water with salt concentration of 10000 mg/L as the feed solution under diverse hot feed temperatures (Tf) and flow rates (Mf). Experimental results revealed that the percentage of AGMD permeate flux was reduced by 4.71%, 4.98%, 7.51%, 1.84%, 2.71%, 8.20%, 2.25% and 4.42% at increasing cooling temperature from 10 to 20 oC, respectively, in case of flow rate (Mf) of 2.0 and 4.0 L/m (temperature Tf of 50 oC), 6.0 and 8.0 L/m (temperature Tf of 50, 60 and 70 oC) due to lowering the temperature and vapor pressure differences between the hot and the cold feed at both sides of the membrane (ΔTcross=T1-T4). Regarding thermal efficiency (η), an opposite result was obtained whereas the thermal efficiency was improved significantly at increasing cooling temperature from 10 to 20 oC at all different operating conditions. The rate of increasing in thermal efficiency were around 1.26, 1.29, 1.15 and 1.27 times at flow rate Mf of 2 L/m and different temperature Tf of 50, 60, 70 and 80 oC, respectively.
Summary in Arabic.