Effect of using a new automatic heating system powered by renewable energy on poultry houses [electronic resource]
Language: English Summary language: Arabic Description: 81 - 92 pOther title:- تأثير إستخدام نظام تدفئة جديد أتوماتيكى يعمل بالطاقة المتجددة على عنابر الدواجن [Added title page title]
- Zagazig journal of agricultural research, 2023 v. 50 (1) [electronic resource]
Item type | Current library | Call number | Status | Date due | Barcode | |
---|---|---|---|---|---|---|
Articles | Main | ART ZJAR V50 No1 7 (Browse shelf(Opens below)) | Available |
Includes bibliographic reference
A new automatic simple heating technique was established to improve performance within poultry houses using renewable energy sources (Biogas energy). Four different heating systems were used in the work as follow: H.S1; Conventional heating system using the cylinder of Liquefied Petroleum Gas LPG with open direct fire flame. H.S2; Heating system using Biogas energy and the cylinder of LPG with open direct fire flame manual converting. H.S3; Heating system using the cylinder of LPG with the automatic manufacturing heater and air distribution perforating tube. H.S4; Heating system using Biogas energy and the cylinder of LPG with the automatic manufacturing heater and air distribution tube. The obtained results revealed that using Biogas increase poultry body weight/bird after 6 weeks by about 3%, and by about 4% approximately in total body weights, and increase production efficiency factor (PEF) by about 10.3% compared to conventional system. Also, applying H.S4 increase poultry body weight/bird about 175 and 163% after first and second week respectively compared with the initial stage. In addition, increase the poultry weight/bird after 6 weeks by about 30%. Applying new system, also increase feed intake ranging about 6-8%, and decrease Feed conservation ratio ranging 29- 33%. Applying a new system and using biogas increasing the survival ratio by about 6%, sequent decrease mortality rate. In addition, increase PEF by about 85% comparing with conventional. Applying H.S4 the total energy decreased by about 53%, Also the specific energy requirements (SER) highly improving where decreased by about 66% comparing with H.S1.
Key words: Biogas, LPG, Automated heating system, Poultry houses
Summary in Arabic
There are no comments on this title.